PostPosted: Tue Apr 05, 2016 10:04 am    Post subject: Thermal bridge - slab detail Reply with quote

Back with another Ecodesigner thermal bridge question. Is it possible to exam the centre of a floor slab? There is no external air at this point but the first stage demands this is designated before allowing me to proceed.

Do I have to attempt one for the whole slab?



slab centre.png
 Description:
 Filesize:  202.3 KB
 Viewed:  152 Time(s)

slab centre.png


Back to top
View user's profile Send private message Visit poster's website    
Vahur
Junior member
Junior member

Joined: 01 Jul 2014
Posts: 64
Location: Estonia

PostPosted: Wed Apr 06, 2016 9:43 pm    Post subject: Re: Thermal bridge - slab detail Reply with quote

Can you explain what are you going to achieve by such a simulation? Energy loss into slab? Why is there energy loss at all? Some environment, which is always colder/warmer comparing to internal air?
This calculation/smulation is all about thermodynamics. Heat flow is there, where is temperatures difference only. Temperature difference is the neccessary condition.

_________________
i7-3770K, 32 GB RAM, FirePRO W8100 8 GB.
Windows 10 PRO x64. AC10-21
Current: AC 20 5025 INT
Back to top
View user's profile Send private message    
laszlonagy
Site Admin
Site Admin

Joined: 20 Oct 2003
Posts: 7915
Location: Budapest, Hungary

PostPosted: Sun Apr 10, 2016 11:23 pm    Post subject: Re: Thermal bridge - slab detail Reply with quote

I think the attached image shows a situation where the slab is on soil, which is mostly colder than the interior temperatures. So there is some heat loss in that direction which needs to be taken into consideration.

The above simulation seems to be able to handle with above ground condition. This is why you have to specify the external air. Unfortunately I am not familiar with it enough to say if it can do below ground as well.

_________________

Laszlo Nagy, Moderator, Site Admin
https://twitter.com/laszlonagy

i7-2630QM 16 GB RAM
17.3" (1920x1080), NVidia GTX 460M
SSD+HDD, Win10-64 ENG
AC13-AC21 (64-bit, latest build)
Loving ARCHICAD since 1995
Back to top
View user's profile Send private message Visit poster's website    
Vahur
Junior member
Junior member

Joined: 01 Jul 2014
Posts: 64
Location: Estonia

PostPosted: Mon Apr 11, 2016 5:18 pm    Post subject: Re: Thermal bridge - slab detail Reply with quote

I have qualification in this field, so I can explain some things.
Take a look at the following file.
https://www.dropbox.com/s/rzl35vdoya2v3ri/PSI%20Kulmasilla%20arvutus%20ENG.pdf?dl=0
I explain there how to make the proper calculation of PSI value.
There is a bit simplier way, but I wanted to go deeper =)

_________________
i7-3770K, 32 GB RAM, FirePRO W8100 8 GB.
Windows 10 PRO x64. AC10-21
Current: AC 20 5025 INT
Back to top
View user's profile Send private message    
Rob Annable
New member
New member

Joined: 14 Aug 2011
Posts: 6
Location: Birmingham UK

PostPosted: Thu Apr 14, 2016 6:13 pm    Post subject: Re: Thermal bridge - slab detail Reply with quote

Vahur - thanks for the link, I think I understand it. Very helpful.

Laszlo - that's correct, there is heat loss into the ground at this junction but unfortunately there appears to be no way to calculate it as I can't proceed without describing external air area.
Back to top
View user's profile Send private message Visit poster's website    
Vahur
Junior member
Junior member

Joined: 01 Jul 2014
Posts: 64
Location: Estonia

PostPosted: Fri Apr 15, 2016 6:11 am    Post subject: Re: Thermal bridge - slab detail Reply with quote

Rob Annable wrote:
Vahur - thanks for the link, I think I understand it. Very helpful.

Laszlo - that's correct, there is heat loss into the ground at this junction but unfortunately there appears to be no way to calculate it as I can't proceed without describing external air area.



Ground in this tool is working quite funny way. It is just a material and not considering the constant temperature below freezing level. I would gladly discuss the calculation method with Graphisoft energy efficiency engineers. (if they have one)

Rob, just take a bigger part of building to make this simulation. Our Estonian engineers have a rule to take piece of ground 20 m apart from building and in depth. Temperature constant is +7oC, building floor at least 4m from wall into the building, 3x width of wall height. This is our local rule to define PSI value of wall-floor-foundation thermal bridge.

_________________
i7-3770K, 32 GB RAM, FirePRO W8100 8 GB.
Windows 10 PRO x64. AC10-21
Current: AC 20 5025 INT
Back to top
View user's profile Send private message    
laszlonagy
Site Admin
Site Admin

Joined: 20 Oct 2003
Posts: 7915
Location: Budapest, Hungary

PostPosted: Tue Apr 19, 2016 6:16 am    Post subject: Re: Thermal bridge - slab detail Reply with quote

I asked the guys at GRAPHISOFT about this.
I was told that you could simply specify the soil fill as "External Air" and specify the temperature of the soil for it. The results should still be correct this way.
Then, in the next Dialog, you would not define a "Soil".
This is a workaround but it will achieve what you are trying to do.

_________________

Laszlo Nagy, Moderator, Site Admin
https://twitter.com/laszlonagy

i7-2630QM 16 GB RAM
17.3" (1920x1080), NVidia GTX 460M
SSD+HDD, Win10-64 ENG
AC13-AC21 (64-bit, latest build)
Loving ARCHICAD since 1995
Back to top
View user's profile Send private message Visit poster's website    
Vahur
Junior member
Junior member

Joined: 01 Jul 2014
Posts: 64
Location: Estonia

PostPosted: Tue Apr 19, 2016 8:54 am    Post subject: Re: Thermal bridge - slab detail Reply with quote

laszlonagy wrote:
I asked the guys at GRAPHISOFT about this.
I was told that you could simply specify the soil fill as "External Air" and specify the temperature of the soil for it. The results should still be correct this way.
Then, in the next Dialog, you would not define a "Soil".
This is a workaround but it will achieve what you are trying to do.

This is not workaround. This is the only proper way. The "Soil" environment is not a working tool at all. It is not working as it should do. Currently it works as a simple material, but is not analyzed during the calculation.
Also, there is no point (in the current edition) to define the temperature at all. unless you are interested in the temperature inside the construction. Anyway L2D value (for some reason called PSI in EcoDesigner) has units W/mK. So there must be just the temperature difference, no matter how big. Inportant are the surface resistances.
Maybe Graphisoft wants me as the energy efficiency engineer in their team?
Laughing

_________________
i7-3770K, 32 GB RAM, FirePRO W8100 8 GB.
Windows 10 PRO x64. AC10-21
Current: AC 20 5025 INT
Back to top
View user's profile Send private message    
Display posts from previous:   
View previous topic :: View next topic
Post new topic   Reply to topic   printer-friendly view       ArchiCAD-Talk Forum Index >>> Sustainable Architecture >>> Thermal bridge - slab detail All times are GMT + 1 Hour
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum


Powered by phpBB 2001, 2005 phpBB Group
Copyright 2012 - Graphisoft SE. All rights reserved worldwide. Terms of Use | Privacy Policy