hello,

I have on one floor (hight +3,33) a platform (hight 3,96). They are both a part of the same level. Now I have a door on the platform, hight 2,26m. When I drew a measuring line next to it, it calculated the hight of the entire room, resulting in a door-hight of 2,895 (door hight+platform hight = 2,26 + 0,635 = 2,895).

Is there a way of chaining this, without having to edit manually the value on the measuring line ?



Screen Shot 2017-08-03 at 11.11.48.png
 Description:
 Filesize:  65.73 KB
 Viewed:  22 Time(s)

Screen Shot 2017-08-03 at 11.11.48.png


Back to top
View user's profile Send private message    
laszlonagy
Site Admin
Site Admin

Joined: 20 Oct 2003
Posts: 8005
Location: Budapest, Hungary

PostPosted: Sat Aug 05, 2017 9:43 am    Post subject: Re: Measuring a door in a ground plan - hight difference Reply with quote

Is the size of the Door Opening larger than the actual Door itself?
Which AC version? Linear Dimensioning options have been added in the last few releases so the answer may depend on your version.
Could you show me a 3D of the Door as well?
And also a screenshot, with the placed Dimension selected, showing the Dimension Details panel of the Dimension Settings Dialog?

_________________

Laszlo Nagy, Moderator, Site Admin
https://twitter.com/laszlonagy

i7-2630QM 16 GB RAM
17.3" (1920x1080), NVidia GTX 460M
SSD+HDD, Win10-64 ENG
AC13-AC21 (64-bit, latest build)
Loving ARCHICAD since 1995
Back to top
View user's profile Send private message Visit poster's website    
Display posts from previous:   
View previous topic :: View next topic
Post new topic   Reply to topic   printer-friendly view       ArchiCAD-Talk Forum Index >>> Construction Documentation >>> Measuring a door in a ground plan - hight difference All times are GMT + 1 Hour
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum


Powered by phpBB 2001, 2005 phpBB Group
Copyright 2012 - Graphisoft SE. All rights reserved worldwide. Terms of Use | Privacy Policy