mnguyen wrote:
Sat Apr 25, 2020 8:23 pm
stetuv wrote:
Sat Apr 25, 2020 7:27 pm
Hi James, did you solve your issue? I'm also interested in the exportation workflow from Archidad to PHPP, If yes would you be so kind to share your experience?
Hi,

Thank you for your interest in the issue!

May I ask what can I help you with? We have some articles about Energy Evaluation workflow in our HelpCenter. You can always have a look here, or if you have any specific questions, feel free to let me know!

Have a nice weekend, and stay safe!

Best regards,
Minh
Hi,
thank you for the fast reply. I am starting to study how works the Energy Evaluation in Archicad and I am also interested in how the data can be exported to fill properly a PHPP file to make a Passivhaus simulation. At the moment I have not a specific question yet but as James has talked about some issues during the exportation, I was curious to know what happened. I have a feeling that it might depend on how the model has been created and the fact that "a classical BIM model" with 3D structure components might not work for a PHPP file. For example when you create the model using the DesingPH app (that works on Sketchup) its componentes are made of simple flat surfaces (with no thikness). Anyway, do you have a guide that explains how to create the model for PHPP exportation?

KR
#310237
stetuv wrote:
Sun Apr 26, 2020 11:49 am

Hi,
thank you for the fast reply. I am starting to study how works the Energy Evaluation in Archicad and I am also interested in how the data can be exported to fill properly a PHPP file to make a Passivhaus simulation. At the moment I have not a specific question yet but as James has talked about some issues during the exportation, I was curious to know what happened. I have a feeling that it might depend on how the model has been created and the fact that "a classical BIM model" with 3D structure components might not work for a PHPP file. For example when you create the model using the DesingPH app (that works on Sketchup) its componentes are made of simple flat surfaces (with no thikness). Anyway, do you have a guide that explains how to create the model for PHPP exportation?

KR
Hi,

Let me first share with you our official guide on how to use Energy Evaluation feature and the EcoDesigner STAR manual, so that you can find out how the tool works:

Energy Evaluation Guide: https://helpcenter.graphisoft.com/user- ... ter/85167/

EcoDesigner STAR Guide: https://www.graphisoft.com/ftp/marketin ... Manual.pdf

I would like to emphasize one important point about the Energy Evaluation feature: ARCHICAD's Energy Evaluation and EcoDesigner STAR features are not a certification or auditing tool for energy evaluation purposes. It is a design-aid tool, hence it is found under the Design bar menu.

With regard to PHPP, we are currently compatible with the PHPP v9 Excel sheet. ARCHICAD can export and implement some of the information needed for the PHPP certificate, but not everything (again, Energy Evaluation and EcoDesigner STAR features are just a design-aid tool to help architects in energy-conscious design).

Exporting to PHPP v9 is done directly within ARCHICAD's Energy Model Review palette, given that a proper BEM (Building Energy Model) is formed and a PHPP v9 or older Excel template is available. When you wish to export to PHPP, a prompt dialog asks to browse for the said PHPP excel sheet.

I hope this will help you with using the tool!

Thank you very much!

Best regards,
Minh
#312309
I spent some time on this issue and this is where the main problem comes from. PHPP needs the total surface area to the outside face of any assembly (wall, roof, floor). Technically, it's to the outside face of the exterior insulation, but to keep things simple, let's try to get it to the outside face of the assembly.

The way that the AC Energy Model exports the surface areas currently is to the inside face of the assemblies (see attachments). This is the data that is received by PHPP during the export.

I created a morph to show what we would want, and scheduled it according to what PHPP needs. I also created some additional properties in order to schedule this.

The area for the highlighted wall (the south wall) according to the Energy Model is 198 sq ft, but if you look at the morph I created, that area is supposed to be 395 sq ft.

The thing that is being exported correctly are the openings. We want the rough opening dimensions to be exported into PHPP, and the AC Energy Model does just that.

What would be great is if we could assign morphs as structures for this export to PHPP, as I've seen that getting an accurate exterior surface area from ArchiCAD doesn't always work as we would like it to. I had to create a property to do this accurately, where I multiply the length of the Wall Reference Line by the total Height of the Wall. However, the problem with that is that sometimes we will need to assign areas with a different exterior conditions which most times don't fit exactly the surface areas of a specific wall, hence having the flexibility of a morph would be great.

Furthermore, the export to PHPP does not work well with the IP version of the software.

As of right now, I would like to know if we could export specific portions of schedules to specific areas of an Excel sheet. That seems to be exactly what the Energy Model export is doing, so if we could modify that as we need it, that would excellent!

Thank you for your help with this.
Attachments
AC - ENERGY MODEL - WALL AREA INCORRECT.png
Thermal Block - Interior Areas
AC - ENERGY MODEL - WALL AREA INCORRECT - HIGHLIGHT.png
Thermal Block - Area highlighted
AC - ENERGY MODEL - WALL AREA PHPP CORRECT.png
PHPP - Exterior Surface Area
AC - ENERGY MODEL - WALL AREA PHPP CORRECT - HIGHLIGHT.png
PHPP - Exterior Area highlighted
#312607
jrmrt wrote:
Sun Jun 21, 2020 5:54 pm
I spent some time on this issue and this is where the main problem comes from. PHPP needs the total surface area to the outside face of any assembly (wall, roof, floor). Technically, it's to the outside face of the exterior insulation, but to keep things simple, let's try to get it to the outside face of the assembly.

The way that the AC Energy Model exports the surface areas currently is to the inside face of the assemblies (see attachments). This is the data that is received by PHPP during the export.

I created a morph to show what we would want, and scheduled it according to what PHPP needs. I also created some additional properties in order to schedule this.

The area for the highlighted wall (the south wall) according to the Energy Model is 198 sq ft, but if you look at the morph I created, that area is supposed to be 395 sq ft.

The thing that is being exported correctly are the openings. We want the rough opening dimensions to be exported into PHPP, and the AC Energy Model does just that.

What would be great is if we could assign morphs as structures for this export to PHPP, as I've seen that getting an accurate exterior surface area from ArchiCAD doesn't always work as we would like it to. I had to create a property to do this accurately, where I multiply the length of the Wall Reference Line by the total Height of the Wall. However, the problem with that is that sometimes we will need to assign areas with a different exterior conditions which most times don't fit exactly the surface areas of a specific wall, hence having the flexibility of a morph would be great.

Furthermore, the export to PHPP does not work well with the IP version of the software.

As of right now, I would like to know if we could export specific portions of schedules to specific areas of an Excel sheet. That seems to be exactly what the Energy Model export is doing, so if we could modify that as we need it, that would excellent!

Thank you for your help with this.
Hi,

Thank you for sharing your experience with EcoDesigner!

Unfortunately, it is correct that, the way we are handling surface areas in EcoDesigner is not in sync with PHPP. Right now ARCHICAD indeed only considers the inside face of the exterior assemblies (walls, roofs, etc.). The exterior face of the exterior assemblies are not considered.

I hope that in the future, we can provide more options in order to support more Energy Evaluation standards.

Thank you for your understanding! Have a great day!

Best regards,
Minh
#312611
If this is the case, then as I have been stating all this time, the PHPP export feature is useless as the User completing the PHPP then has to manually add in the extra area for it to be valid, which, to be honest, will be more onerous than just manually doing it in the first place...... :?